Replace chemical filter approximately every twelve months OR immediately following any detection of Rhodium or other odor from the discharge of the system.
To Replace Your Odor Filter
- Ensure that the unit is unplugged, open door with appropriate tool.
- Pull out the existing S-SV2-0003 or S-SV2-0004, remove new S-SV2-0003 or S-SV2-0004 from the box that it was shipped in.
- Reinsert new filter back into the system (ensure airflow arrows are pointing up).
- Close door and verify that an airtight seal is maintained.
To Refill Existing S-SV2-0003 or S-SV2-0004 Filter Cell with New Odor Filters
- Pull out existing S-SV2-0003 or S-SV2-0004 filter.
- Unscrew the two top panel covers and lift off cover.
- Pour out used odor filter (wearing a dust mask is recommended).
- Refill container with fresh odor filters.
- Replace the 2 panel covers and re-insert into unit.
IMPORTANT: Filter disposal is the responsibility of the end-user. Please contact local authorities.
Resetting “Service Filter(s)” Alert
- Ensure filter access door is closed.
- Plug power back to the unit.
- Press & hold SPEED UP & DN simultaneously until unit beeps.
- Hold for 10+ seconds, when panel is beeping continuously, release buttons.
- You are now in RESET MENU, in this condition, “System ON” LED is flashing quickly.
- Press SPEED DN- 2 times until “Service Filter(s)” LED is flashing.
- Press & HOLD POWER button while “Service Filter(s)” LED is flashing & unit is beeping continuously.
- Release, when LED stops flashing & stops beeping.